General The 30-3013 Explosion Proof Smoke Detector has Division and Zone explosion-proof ratings and is suitable for industrial and commercial applications. The detector is designed to operate effectively with smoldering and rapidly growing fires and contains the ability to annunciate fault ensuring no undis- closed failures. The 30-3013 Smoke Detector outputs include 0-20 mA, a localized LED, and relays. DN-60911:A Features •IECEx Zone approved •Trouble-free photoelectric operation •0-20 mA output for DCS integration •Self-checking circuitry ensures reliable smoke detection •Alarm, Auxiliary and Fault relays for controlling annunciat- ing devices or fire panel interface •LED provides a visual indication that an alarm has occurred •IP44 ingress protection level suitable for onshore or off- shore requirements •Ideally suited for classified areas in the petrochemical, oil and gas industry •DCS, PLC, integration with milliamp or relay outputs •Rugged design for environmental extremes •Visual confirmation of detector alarm •Detects smoldering fires •No undisclosed failures Applications •Combustible storage facilities •Munitions manufacturing •Volatile chemical storage •Chemical processing plants •Petroleum refineries •Turbine enclosures •Battery rooms •HVAC applications The hot-swappable sensor module is intrinsically safe and allows live maintenance while under power, without de-classi- fying the hazardous area. The integrated junction box is avail- able in a variety of port configurations for simplified wiring and installation. Certifications FM Approved •Class 1 Div 1 Groups B, C. D T4 •Class 1 Div 2 Groups A, B, C, D, T4 •Class 1 Zone1 AWX db ia llC T4 Gb IEC/IECx •FMG 15.0014X •Ex db ia llC T4 Gb Specifications Power Consumption 3.5 watts maximum (2.75 watts at 24 VDC) Output Relays •Smoke alarm relay, Form C, 5 amperes at 30 VDC. The smoke alarm relay has normally open/normally closed con- tacts and normally de-energized operation. •Fault relay, Form A, 5 amperes at 30 VDC.The fault relay has normally open contacts and normally energized opera- tion. •Auxiliary relay, Form C, 5 amperes at 30 VDC. The auxiliary relay has normally open/normally closed contacts and nor- mally de-energized operation. Temperature Range •Operating: –20°C to 65°C (–4°F to 149°F) •Storage: –55°C to 70°C (–67°F to 158°F) Humidity Range 5 to 95% relative humidity. Ingress Protection IP44 (Applicable to ceiling mount only). Current Output 0-20 mA (±0.3 mA) DC current, with maxi- mum loop resistance of 300 ohms from 12-17.9 VDC, 500 ohms from 18 to 19.9 VDC, and 600 ohms from 20-30 VDC. Terminals UL/CSA rated for 14-18 AWG or 2.5-0.75 mm2 wire. Thread Options 3/4 inch NPT or M25. Multi-port models avail- able. Enclosure Material Polycarbonate / ABS - Smoke Detector. Copper-free aluminum (painted) - Junction Box. Shipping Weight (Approximate) 7.85 lbs (3.56 kg).